The Journal of Minimally Invasive Gynecology
Volume 17, Issue 3 , Pages 365-370 , May 2010

Tensile Strength of Surgical Knots Performed with the da Vinci Surgical Robot

  • Pétur Reynisson, MD

      Affiliations

    • Department of Obstetrics and Gynecology, Lund University Hospital and Lund University, Lund, Sweden
    • Corresponding Author InformationCorresponding author: Pétur Reynisson, Department of Obstetrics and Gynecology, University Hospital, SE-221 85 Lund, Sweden.
  • ,
  • Ebi Shokri, MSc

      Affiliations

    • Tetra Pak Development & Engineering, Lund, Sweden
  • ,
  • Pär-Ola Bendahl, PhD

      Affiliations

    • Department of Oncology, Clinical Sciences, Lund University, Lund, Sweden
  • ,
  • Jan Persson, MD, PhD

      Affiliations

    • Department of Obstetrics and Gynecology, Lund University Hospital and Lund University, Lund, Sweden

Received 2 October 2009 ,Accepted 8 January 2010.

References 

  1. Krambeck AE, DiMarco DS, Rangel LJ, et al. Radical prostatectomy for prostatic adenocarcinoma: a matched comparison of open retropubic and robot-assisted techniques. BJU Int. 2009;103:448–453
  2. Persson J, Reynisson P, Borgfeldt C, Kannisto P, Lindahl B, Bossmar T. Robot assisted laparoscopic radical hysterectomy and pelvic lymphadenectomy with short and long term morbidity data. Gynecol Oncol. 2009;113:185–190
  3. Bodner JC, Zitt M, Ott H, et al. Robotic-assisted thoracoscopic surgery (RATS) for benign and malignant esophageal tumors. Ann Thorac Surg. 2005;80:1202–1206
  4. Brunaud L, Ayav A, Zarnegar R, et al. Prospective evaluation of 100 robotic-assisted unilateral adrenalectomies. Surgery. 2008;144:995–1001
  5. Trimbos JB. Security of various knots commonly used in surgical practice. Obstet Gynecol. 1984;64:274–280
  6. Marshall DC. Attention Surgeons: Important Educational Notice. Somerville, NJ: Ethicon Inc; 1994;
  7. Hurt J, Unger JB, Ivy JJ, Mukherjee D, Pizzaro A. Tying a loop-to-strand suture: is it safe?. Am J Obstet Gynecol. 2005;192:1094–1097
  8. Kho RM, Akl MN, Cornella JL, Magtibay PM, Wechter ME, Magrina JF. Incidence and characteristics of patients with vaginal cuff dehiscence after robotic procedures. Obstet Gynecol. 2009;114(2 pt 1):231–235
  9. Muffly T, McCormick TC, Dean J, Bonham A, Hill R. An evaluation of knot integrity when tied robotically and conventionally. Am J Obstet Gynecol. 2009;200:e18–e20
  10. Ritter EM, McClusky DA, Gallagher AG, Smith CD. Real-time objective assessment of knot quality with a portable tensiometer is superior to execution time for assessment of laparoscopic knot-tying performance. Surg Innov. 2005;12:233–237
  11. Amortegui JD, Restrepo H. Knot security in laparoscopic surgery: a comparative study with conventional knots. Surg Endosc. 2002;16:1598–1602
  12. Schubert DC, Unger JB, Mukherjee D, Perrone JF. Mechanical performance of knots using braided and monofilament absorbable sutures. Am J Obstet Gynecol. 2002;187:1438–1440
  13. Thacker JG, Rodeheaver G, Kurtz L, Edgerton MT, Edlich RF. Mechanical performance of sutures in surgery. Am J Surg. 1977;133:713–715
  14. Komatsu F, Mori R, Uchio Y. Optimum surgical suture material and methods to obtain high tensile strength at knots: problems of conventional knots and the reinforcement effect of adhesive agent. J Orthop Sci. 2006;11:70–74

 The authors have no commercial, proprietary, or financial interest in the products or companies described in this article.

PII: S1553-4650(10)00007-5

doi: 10.1016/j.jmig.2010.01.005

The Journal of Minimally Invasive Gynecology
Volume 17, Issue 3 , Pages 365-370 , May 2010