The Journal of Minimally Invasive Gynecology
Volume 14, Issue 2 , Pages 233-239, March 2007

A newly developed morcellator creates a new dimension in minimally invasive surgery

  • S. Brucker, MD

      Affiliations

    • Department of Obstetrics and Gynecology, Tübingen University Hospital, Tübingen, Germany
  • ,
  • E. Solomayer, MD

      Affiliations

    • Department of Obstetrics and Gynecology, Tübingen University Hospital, Tübingen, Germany
  • ,
  • W. Zubke, MD

      Affiliations

    • Department of Obstetrics and Gynecology, Tübingen University Hospital, Tübingen, Germany
  • ,
  • S. Sawalhe, MD

      Affiliations

    • Department of Obstetrics and Gynecology, Kreisklinikum Dingolfing-Landau, Dingolfing, Germany
  • ,
  • A. Wattiez, MD

      Affiliations

    • IRCAD-EITS, Hôpital Civil, Strasbourg, France.
  • ,
  • D. Wallwiener, MD

      Affiliations

    • Department of Obstetrics and Gynecology, Tübingen University Hospital, Tübingen, Germany
    • Corresponding Author InformationCorresponding author: Professor Diethelm Wallwiener, Department of Obstetrics and Gynecology, Tübingen University Hospital, Calwerstrasse 7, 72076 Tübingen, Germany.

Received 19 May 2006; accepted 7 October 2006.

Abstract 

We compared the efficiency and safety of a newly developed morcellator with a conventional device for minimally invasive supracervical hysterectomy. The prospective, randomized parallel-group study was set in a department of obstetrics and gynecology within an Academic Teaching Hospital. Patients included 48 women; 20 treated with an existing laparoscopic morcellator (Group 1); 28 treated with newly developed laparoscopic morcellator (Group 2). The weight-adjusted dissection time was reduced significantly by more than half with the new morcellator (p <.01). Significantly fewer (p <.05) and longer pieces of tissue were removed with the new morcellator. The median weight of morcellated tissue in Group 1 was 120 g (range 35–450 g), and the median operating time to remove the morcellated tissue was 10 minutes (range 2–45 minutes). The corresponding figures in Group 2 were 110 g (range 50–320 g) and 4 minutes (range 0.5–12 minutes). No bladder or intestinal lesions or other iatrogenic organ damage was seen with either morcellator. None of the patients in either group had postoperative complications. All interventions were completed as planned in both groups, and none of the procedures had to be converted to an open operation. Adequate tissue for histologic analysis was obtained from all patients. We concluded that the newly developed morcellator is a safe and effective instrument for laparoscopic supracervical hysterectomy, offering a much shorter operation time for the removal of morcellated tissue than a conventional device and a low risk of injury to surrounding organs and tissue.

Keywords: Laparoscopic morcellator, Laparoscopic supracervical hysterectomy, Laparoscopic myomectomy, Minimally invasive surgery

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Supported by the German Ministry of Education and Research (BMBF) within the Minimally Invasive Technology and Therapeutic Methods Project (Grant No. 16SV 1352).

 The authors have no commercial, proprietary, or financial interest in the products or companies described in this article.

PII: S1553-4650(06)00546-2

doi:10.1016/j.jmig.2006.10.004

The Journal of Minimally Invasive Gynecology
Volume 14, Issue 2 , Pages 233-239, March 2007